What Is a Vacuum Hydrogen Meter Used For?
Hydrogen dissolved in molten aluminum comes out during solidification and forms porosity in the casting. A vacuum hydrogen meter lets foundry teams check the melt before pouring, compare results before and after degassing, and decide whether more degassing is needed.
- Furnace-side checks for aluminum ingot and aluminum alloy casting
- Melt quality control for aluminum die casting, gravity casting and investment casting (lost-wax casting)
- Comparing degassing equipment and degassing conditions
- Material analysis and quality research
Frequently Asked Questions
What is the reduced pressure test (RPT)?
A small sample of molten aluminum solidifies in a vacuum chamber under negative pressure. Dissolved hydrogen expands and forms bubbles or surface inflation, which shows how much gas the melt contains compared with other samples.
How long does one test take?
About 5 minutes, and it can be done at the furnace side.
How do I read the result?
Check the sample surface, or cut the sample open and inspect the internal porosity.
Can it replace an online hydrogen analyzer?
They serve different purposes. An online analyzer measures a hydrogen value directly. The reduced pressure test is mainly used for quick comparison on the shop floor and for judging degassing results, and it is relatively simple to operate.
How much sample does one test need?
What power supply does it need?
What maintenance does it need?
Replace the vacuum oil every 500 working hours.